Z275 Galvanized Steel Sheet – Ducting and Roofing Grade - PROGRÈS

Tél: +86-13969518618    E-mail: sales@qidamt.com

À propos Contact |

GALVANIZED · Z275 SHEET

Z275 Galvanized Steel Sheet

Hot-dip zinc coated flat sheet, 0.4–3.0 mm, cut to 1000×2000 / 1250×2500 mm.

Z275 galvanized steel sheet is a flat, hot-dip zinc coated sheet with a total coating mass of 275 g/m² — about 19 µm of zinc on each surface. It is the standard choice for ducting, roofing accessories, flashing, gutters and general outdoor fabrication where the sheet is cut, folded and installed without further coating. QIDAMT supplies Z275 sheet cut to length, with regular spangle or skin-passed surface, in bundles for export.

This page explains what Z275 actually means, how it compares with Z120 and with ASTM A653 G90, the thickness and flatness limits that matter for folding and duct work, and the detailing rules that decide whether the sheet lasts ten years or three.

What Z275 Sheet Is Used For

  • Conduits CVC, plenum boxes and duct fittings
  • Feuilles de toiture, ridge caps, flashings and gutters
  • Rainwater goods, downpipes and drainage components
  • Silo and tank cladding, hoppers and chutes
  • Signage backing, electrical enclosures and cable trays
  • General sheet metal work exposed to weather

What the Z275 Coating Means

The Z designation gives the total zinc mass on both surfaces in grams per square metre. Z275 therefore means 275 g/m² total, ou environ 137.5 g/m² par face. With zinc at 7.14 g/cm³, that is roughly 19 µm per surface. The coating is applied on a continuous hot-dip line, and the zinc-iron alloy layer at the interface provides the bond.

enrobageTotal g/m²Approx µm per sideUtilisation typique
Z1001007Intérieur, peint
Z1201208 – 9Intérieur, light outdoor
Z18018012 – 13Sheltered outdoor
Z27527519De plein air, conduit, toiture
Z35035024 – 25Côtier, severe exposure

ASTM A653 G90 is approximately equivalent to Z275: both describe a total coating of about 0.90 oz/ft². They are not identical designations, so a project specifying G90 should be supplied against A653, not simply relabelled Z275.

 -  - 1
Z275 sheet stacked with interleaving — the spangled zinc surface is visible on the top sheet.

Base Metal and Mechanical Properties

Z275 coating is normally applied to DX51D or an equivalent commercial-quality substrate. The coating does not add meaningful strength; the mechanical properties come from the steel underneath.

PropriétéValeur typiqueNote
Qualité de baseDX51D / commercial qualityConfirm on the certificate
Limite d'élasticité140 – 300 MPaWide band typical of DX51D
Résistance à la traction270 – 420 MPaAdequate for folding and profiling
Élongation≥26% (A80)Good for bending and lock forming
Coating adhesionNo flaking on 180° bendCheck on the sample, not the certificate

Épaisseur, Size and Flatness

ArticleGammeStock sizes
Épaisseur0.4 – 3.0 mm0.5, 0.6, 0.8, 1.0, 1.2, 1.5, 2.0 mm
Largeur600 – 1500 mm1000, 1219, 1250 mm
Longueur1000 – 3000 mm2000, 2438, 2500 mm
ToléranceThickness ±0.05 mm typicalConfirm per EN 10143 / ASTM A924
Platitude≤ 6 mm per metre typicalCritical for duct seams and roofing
BordBord fendu ou fraiséSlit edge for square blanks

Flatness is the specification most often left out and most often disputed. A sheet within thickness tolerance can still be bowed enough to spring open a folded duct seam. For duct work and roofing, specify flatness and ask for a sample sheet before the full order.

Folding, Profiling and Joining

  • Set the folding radius to at least 1.5 – 2 fois l'épaisseur; a sharp 90° fold concentrates stress and can crack the coating at the outside radius.
  • Use nylon or polyurethane-faced tooling where the visible surface must stay unmarked.
  • For lock-seam duct joints, keep the zinc surface clean and dry; oil residue prevents a tight seam.
  • Spot welding wears electrodes faster on coated sheet — dress them regularly and control current.
  • For soldering, use a zinc-compatible flux and clean the joint afterwards; residual flux causes corrosion.
  • Repair cut edges, drilled holes and weld zones with a zinc-rich primer before installation.

Règles de sélection

Z275 or Z120?

Z275 for anything exposed to weather, washing or condensation. Z120 for indoor ducting and painted panels in dry service. The price difference is small relative to the cost of premature rust at a cut edge.

Sheet or coil?

Sheet suits duct shops, roofing contractors and low-volume fabrication. Coil suits continuous profiling and high-volume blanking. If you need both flat blanks and profiled parts, buy coil and cut to length rather than holding two separate stocks.

Spangle and surface

Regular spangle is the normal as-cast zinc surface. Skin-passed sheet is smoother and better for painting or visible architectural work. Either way, confirm that the surface is chromate-free and oiled if it will be stored before fabrication.

Erreurs courantes

  • Treating Z275 as equivalent to G90 without checking the standard and certificate.
  • Folding on a sharp die and cracking the coating at the bend.
  • Leaving cut edges unsealed in a coastal or chemical environment.
  • Storing sheets flat on the ground so condensation stains the lower sheets.
  • Painted Z275 sheet specified without a pretreatment compatible with zinc.
  • Mixing galvanized and cold-rolled offcuts in the same scrap bin and losing the traceability.
 -  - 2
Regular spangle on a Z275 sheet — the visible zinc crystal pattern is normal and does not affect corrosion performance.

Corrosion Behaviour in Duct and Roof Service

Ducts and roofs fail at edges, seams and fixings, not in the middle of a panel. The Z275 coating sacrifices itself around a cut edge, but the sacrificial zone is finite: on a 0.5 mm sheet the zinc at a sheared edge is consumed faster than on a 1.5 mm sheet because there is less coating area relative to the exposed steel.

  • Seal cut edges on outdoor work with a zinc-rich primer or an appropriate sealant.
  • Avoid trapped water in laps, gutters and duct seams; wet contact is the main driver of white rust.
  • Separate galvanized sheet from copper and stainless fixings to prevent galvanic attack.
  • Do not store sheets with condensation between them; interleave and keep the bundle ventilated.
  • In coastal or industrial atmospheres, expect shorter intervals between inspections regardless of coating class.

Coupe, Edge Protection and Installation

Shear cutting leaves a burr that exposes bare steel. For duct work, deburr or seal the cut edge; for roofing, cut with a profile that leaves the zinc on the exposed side wherever possible. Drilling and notching should be done before any paint or sealant is applied so the bare edge can be treated.

Pendant l'installation, avoid dragging sheets across each other: the soft zinc surface scratches easily and scratched areas collect dirt and moisture. Use lifting equipment with non-marking pads and stack sheets with interleaving on site.

Liste de contrôle de commande

  • Épaisseur, width and length of each blank
  • Classe de revêtement: Z275 unless the environment justifies Z350
  • Surface: regular spangle or skin-passed
  • Flatness requirement for duct seams or roofing laps
  • État des bords: bord fendu, deburred or mill edge
  • Passivation and oiling for storage duration
  • Bundle weight limit and destination port

Packing and Delivery

Sheets are packed in flat bundles with timber or cardboard interleaving, steel strapped and edge protected. Bundle weight is kept within crane and container limits; for export, desiccant and wrap are added in humid seasons. We supply mill certificates, coating mass records and packing lists with bundle weights.

Foire aux questions

Is Z275 the same as G90?

Approximately, in coating mass: both correspond to about 275 g/m² total. They are different standards (DANS 10346 versus ASTM A653), so the certificate and designation should match the project specification.

What thicknesses do you stock?

0.4 – 3.0 mm; 0.5, 0.6, 0.8, 1.0, 1.2, 1.5 et 2.0 mm are usual stock thicknesses. Other thicknesses are produced on request.

Can the sheet be used for ducting?

Oui, Z275 is widely used for HVAC ducting. Specify flatness suitable for lock forming and confirm that the surface is oiled for storage.

Do you cut to size?

Oui. We cut to width and length, and can supply blanks or notched sheets against a cutting list. Send the drawing and quantity.

Produits connexes

Need Z275 sheet cut to your duct or roofing sizes?

Envoyer l'épaisseur, largeur, longueur, quantité et port de destination. We confirm price, flatness and lead time within 24 heures.

DEMANDER UN DEVIS

    PersonnelEntrepriseDistributeur

    Laisser un commentaire