S350GD+Z Galvanized Steel Coil – Structural Grade, Z275 - FREMSKRIDT

Tlf: +86-13969518618    E-mail: sales@qidamt.com

Om Kontakte |

GALVANIZED · EN 10346 S350GD+Z

S350GD+Z Galvanized Steel Coil

Structural-grade zinc coated coil, 350 MPa minimumsudbytte, Z275 for frames and outdoor structures.

S350GD+Z is a hot-dip galvanized structural steel coil with a 350 MPa minimum yield strength. It lets a frame, purlin or panel carrier be designed at a thinner gauge than DX51D while keeping the corrosion protection of zinc. QIDAMT supplies S350GD+Z in 0.8–3.0 mm, Z100–Z350, slit to width and packed for export.

The grade is common in steel framing, solar mounting, lastbil karosserier, racking and agricultural structures. This page explains the mechanical limits, the coating options, how the higher strength changes forming and welding, and where the grade should not be used.

Where S350GD+Z Coil Is Used

  • Light steel framing, knopper, joists and wall panels
  • Solar mounting rails, brackets and ground-mount structures
  • Truck bodies, trailer panels and refrigerated van liners
  • Warehouse racking, shelving and mezzanine decking
  • Agricultural sheds, livestock equipment and fencing
  • HVAC support frames and equipment housings

The economic case is simple: på 350 MPa udbytte, -en 1.5 mm section can replace a 2.0 mm DX51D section in many bending-dominated parts, saving weight and coating area. The case fails when stiffness, ikke styrke, governs — a thinner gauge flexes more even if the stress is acceptable.

Kemisk sammensætning

ElementLimit (%)Rolle
Kulstof (C)0.20 maxStrength with weldability
Silicium (Og)0.60 maxStyrke; too high hurts coating
Mangan (Mn)1.70 maxHovedforstærkende element
Fosfor (P)0.10 maxSolid solution strengthening
Svovl (S)0.045 maxInclusion control
Aluminium (Al)0.015 minFine grain and deoxidation
NB + Af0.20 maxMicro-alloying for consistent yield

The chemistry is designed to reach 350 MPa without the carbon level that would make welding difficult. That is why S350GD can be spot welded and roll formed on equipment used for thinner commercial grades, provided the gauge and current are adjusted.

Mekaniske egenskaber

EjendomKravDesignnote
Yield strength ReH≥350 MPaUse the certified value, not the minimum
Trækstyrke Rm420 – 560 MPaCheck against connection design
Forlængelse A80≥16%Enough for normal profiling, not deep drawing
BelægningsmasseZ100 – Z350 g/m²Z275 standard for outdoor frames
Tykkelse0.8 – 3.0 mmUnder 0.8 mm forming limits tighten
Spole ID508 / 610 mmConfirm uncoiler capacity

The tensile range is wide because mills balance strength against elongation. A coil at 540 MPa tensile will form differently from one at 430 MPa; for roll-formed profiles, ask for a consistent heat and check the first coil before full production.

 -  - 1
Structural galvanized coils handled with a coil boom — the eye must stay protected to avoiddeforming the inner wraps.

Coating and Surface Options

BelægningSamlet masse (g/m²)Typisk eksponering
Z100100Indendørs, tørre, malet
Z180180Sheltered outdoor, malet
Z275275Udendørs strukturelle, tagdækning, kanalføring
Z350350Severe exposure, coastal or industrial

For structural frames that will be painted, Z275 is the usual balance. For coastal sites or uncoated outdoor use, Z350 extends service life. Remember that the coating protects the steel only while it is continuous; skære kanter, drilled holes and weld zones need a zinc-rich repair coating.

Dannelse, Roll Forming and Welding

S350GD work-hardens more than DX51D, so bending radii should be generous relative to thickness and the bend line should run across the coil width where possible. Springback is higher than commercial grades: a 90° bend may need over-bending of 2 – 4° depending on thickness and tooling.

Roll forming is the natural process for this grade. Set the rolls for the certified yield, keep the strip tension steady and avoid abrupt transitions that can crack the coating at the corners. For profiles with holes, punch before forming only if the distortion is acceptable; otherwise punch after forming.

Svejsning: spot welding is standard for thin gauges; for structural joints, use the procedure qualified for the actual thickness and remove zinc from the weld zone. Do not use S350GD as a substitute for a true structural plate in a welded load path without checking the welding procedure and heat input.

Udvælgelsesregler

  • Match the gauge to the governing case: bending strength, deflection, or local buckling. Higher yield does not improve stiffness.
  • Use Z275 as the default for outdoor frames; upgrade to Z350 only where the coating is exposed and unpainted.
  • For roll-formed profiles, keep the same heat for a production run so springback does not drift.
  • Do not deep draw S350GD; its elongation is adequate for profiling, not for drawing.
  • If the part is painted after forming, specify skin-passed, oiled and chromate-free material and confirm paint compatibility.

Almindelige fejl

  • Replacing 2.0 mm DX51D with 1.5 mm S350GD and assuming the panel will be as stiff.
  • Ignoring springback because the grade is labelled structural.
  • Cutting the coil with a dull blade and leaving a burr that rusts first.
  • Welding through zinc without fume extraction.
  • Mixing S350GD and DX51D parts in the same painted assembly without noting the different surface reactivity.

Corrosion Behaviour and Service Life

The zinc coating protects the steel at scratches, cut edges and fixing points — exactly where painted structural frames fail first. Service life therefore depends on coating mass, exposure category and detailing, not on the yield strength.

  • Rural and indoor service: Z100 – Z180 is usually enough when the part is painted.
  • Urban, industrial and sheltered outdoor service: Z275 is the practical minimum.
  • Kystnære, de-icing salt or ammonia-rich livestock buildings: specify Z350 and inspect cut edges.
  • Water traps, unvented box sections and contact with treated timber shorten life regardless of coating mass.
  • Dissimilar metals in contact (kobber, brass, rustfri) cause galvanic attack on the zinc; isolate with a suitable fastener or coating.

Tolerances and Inspection

PunktNormal supplyCheck before production
Tykkelse±0.05 mm typicalMeasure at three points across the width
Bredde (slids)±0,5 mmCheck both ends of the coil
Camber≤ 5 mm pr 2 mMatters on long roll-formed profiles
Udbyttestyrke≥350 MPa certifiedCompare certificate with trial coil
BelægningsmasseZ100 – Z350Weigh-strip or certificate
OverfladeRegular / skin-passedConfirm for painted parts

Where S350GD+Z Should Not Be Used

  • Deep-drawn parts with sharp radii — use DX52D or DX53D instead.
  • Heavy welded load paths that require a qualified structural plate procedure.
  • Parts where deflection, not stress, governs the design; a thinner high-strength sheet will flex more.
  • High-temperature service where zinc coating degrades or embrittles the steel.
 -  - 2
Structural coils staged for export — the outer wraps show handling contact, so the first metres of each coil are usually trimmed at the customer’s line.

Packing and Delivery

Coils are supplied eye-to-sky or eye-to-wall, spændt med stålbånd, edge-protected and wrapped. For container shipment, the coil weight and eye direction must be fixed before booking; a coil that is too large for the door cannot be loaded later. We supply mill certificates, coating mass records and pre-shipment photos.

Ofte stillede spørgsmål

Is S350GD+Z a structural grade?

Ja. I 10346 defines S350GD with a minimum yield of 350 MPa for structural use. It is not a plate grade and should not be substituted for hot-rolled structural plate in heavy welded connections without engineering review.

What does the Z275 coating mean?

Z275 is a total zinc coating mass of 275 g/m², om 19 µm pr side. It is the usual choice for outdoor structural parts and roofing.

Can S350GD be galvanized after welding?

The coil is already zinc coated. If the finished part is hot-dip galvanized after fabrication, tell us before ordering so the surface and venting can be planned; double coating is not a substitute for correct detailing.

Do you supply slit widths?

Ja. Send finished width, tolerance and edge condition. Slitting is done from master coil with edge protection on the rewound coil.

Relaterede produkter

Need S350GD+Z coil for a structural profile?

Send tykkelse, bredde, coating mass, profile drawing and tonnage. We confirm price, mechanical certificate and lead time within 24 timer.

ANMOD ET TILBUD

    PersonligForretningDistributør

    Efterlad et svar

    Efterlad en besked